2003311023, Muhammad Fadhlurrahman (2023) Kinerja Soft Starting pada Operasi Multi Motor Induksi Tiga Fasa. D3 thesis, Politeknik Negeri Jakart.
Halaman Identitas Tugas Akhir.pdf
Download (2MB)
Isi.pdf
Restricted to Hanya Civitas Akademika PNJ
Download (5MB)
Jurnal.pdf
Restricted to Hanya Staff Repositori
Download (1MB)
Abstrak
Motor induksi merupakan motor listrik AC yang bekerja berdasarkan arus induksi. Motor induksi tiga fasa apabila dihidupkan secara langsung akan menarik arus mula yang besar yang dapat mengakibatkan drop tegangan sehingga mengganggu peralatan lain dalam satu saluran. Metode starting konvensional motor induksi tiga fasa yang sering digunakan seperti Metode DOL menarik arus mula sebesar 7 kali arus nominal sementara Metode Star Delta menarik arus mula sebesar 2 kali arus nominal. Metode Soft Starting menggunakan softstarter yang di dalamnya terdapat thyristor memberikan kenaikan tegangan secara bertahap sehingga mengurangi lonjakan arus mula dan motor berputar sampai kecepatan nominalnya dengan lebih halus. Perancangan sistem Soft Starting menggunakan satu softstarter yang dikombinasikan dengan multi kontaktor juga mampu mengendalikan tegangan dan arus yang masuk ke dalam multi motor secara bergantian satu per satu. Dari beberapa pengujian diperoleh kinerja soft starting berupa penurunan arus starting dengan nilai rata-rata persentase penurunan arus starting untuk motor DOL (Y) sebesar 22,98 persen, motor Forward sebesar 29,84 persen, motor Reverse sebesar 16,46 persen, motor Speed 1 sebesar 81,08 persen, motor Speed 2 sebesar 74,08 persen, motor DOL (Δ) sebesar 91,70 persen, dan motor Star Delta sebesar 82,10 persen. Dengan demikian, masalah starting multi motor induksi tiga fasa dapat diatasi dengan memaksimalkan penggunaan softstarter yang lebih efisien untuk operasi multi motor.
Kata kunci : arus mula, efisien, multi motor induksi tiga fasa, Soft Starting
Induction motor is an AC electric motor that works based on the induced current. A three phase induction motor when started directly will draw a large starting current which can result in a voltage drop that interferes with other equipment in one channel. Conventional starting methods of three-phase induction motors that are often used such as the DOL Method draws a starting current of 7 times the nominal current while the Star Delta Method draws a starting current of 2 times the nominal current. The Soft Starting method using a softstarter in which there is a thyristor provides a gradual increase in voltage thereby reducing the starting current surge and the motor rotates to its nominal speed more smoothly. Soft Starting system design using one softstarter combined with multi contactors is also able to control the voltage and current entering the multi motor alternately one by one. From several tests, the soft starting performance is obtained in the form of a decrease in starting current with an average value of the percentage of starting current reduction for DOL (Y) motor of 22.98 percent, Forward motor of 29.84 percent, Reverse motor of 16.46 percent, Speed 1 motor of 81.08 percent, Speed 2 motor of 74.08 percent, DOL (Δ) motor of 91.70 percent, and Star Delta motor of 82.10 percent. Thus, the starting problem of multi three phase induction motor can be overcome by maximizing the use of a more efficient softstarter for multi motor operations.
Key words : efficient, multi three phase induction motor, Soft Starting, starting current
Tipe Dokumen: | Thesis / Skripsi / Tugas Akhir (D3) |
---|---|
Subjek: | 000 - Komputer, Informasi dan Referensi Umum > 000 Ilmu komputer, ilmu pengetahuan dan sistem-sistem > 001 Ilmu pengetahuan |
Bidang, Unit, atau Jurusan Yang Ditujukan: | Teknik Elektro > Teknik Listrik D3 |